VL-HS | |||||||||
Model
|
1.0KW | 2.0KW | 3.0KW | 4.0KW | 5.0KW | 6.0KW | 8.0KW | 10.0KW | 12.0KW |
Continuous Output Power
|
1.0KW | 2.0KW | 3.0KW | 4.0KW | 5.0KW | 6.0KW | 8.0KW | 10.0KW | 12.0KW |
Surge Rating(20ms)
|
3.0KW | 6.0KW | 9.0KW | 12.0KW | 15.0KW | 18.0KW | 24.0KW | 30.0KW | 36.0KW |
Output voltage waveform
|
Pure Sine wave/Same as input(Bypass Mode)
|
||||||||
Nominal Efficiency
|
>88%(Peak)
|
||||||||
Line Mode Efficiency
|
>95%
|
||||||||
Power factor
|
0.9-1.0
|
||||||||
Nominal Output Voltage rms
|
100-110-120Vac / 220-230-240Vac
|
||||||||
Output Voltage Regulation
|
±10% RMS
|
||||||||
Output Frequency
|
50Hz ± 0.3Hz/60Hz ± 0.3Hz
|
||||||||
Short Circuit Protection
|
Yes( 1sec after fault )
|
||||||||
Typical Transfer Time |
10ms(Max)
|
||||||||
THD
|
< 10%
|
||||||||
Nominal Input Voltage
|
12.0Vdc / 24.0Vdc / 48.0Vdc
|
24.0Vdc / 48.0Vdc
|
48.0Vdc
|
||||||
Minimum starting voltage
|
10.0Vdc / 10.5Vdc for 12Vdc Mode
|
*2 for 24Vdc, *4 for 48Vdc;
|
|||||||
Low battery voltage alarm
|
10.5Vdc / 11.0Vdc for 12Vdc Mode
|
||||||||
Low Battery Trip
|
10.0Vdc / 10.5Vdc for 12Vdc Mode
|
||||||||
High Voltage Alarm
|
16.0Vdc for 12Vdc Mode
|
||||||||
Low Battery voltage recover
|
15.5Vdc for 12Vdc Mode
|
||||||||
Idle Consumption- Search Mode
|
< 25 W when Power Saver On.(Refer to Table )
|
||||||||
Output Voltage
|
Depends on battery type (Refer to Table 2.5.2)
|
||||||||
Charger Breaker Rating
|
10A | 20A | 30A | 40A | 40A | 40A | 50A | 80A | 80A |
Max Charge Power Rate
|
1/3 Rating Power (Refer to Table 2.5.3)
|
||||||||
Battery Initial Voltage for Start
|
10-15.7Vdc for 12Vdc Mode
|
15.7Vdc for 12Vdc Mode
|
|||||||
Over Charge Protection S.D.
|
15.7Vdc for 12Vdc Mode
|
||||||||
Battery Temperature Sensor (Optional)
|
Yes(Refer to the table ) Variances in Charging Voltage & S.D Voltage Base on the Battery Temperature.
|
||||||||
Input Voltage Waveform
|
Sine wave (Grid or Generator)
|
||||||||
Nominal Voltage
|
100-110-120Vac / 220-230-240Vac
|
||||||||
Max Input AC Voltage
|
150VAC For 120Vac LV Mode;300VAC For 230Vac HV Mode;
|
||||||||
Nominal Input Frequency
|
50Hz or 60Hz
|
||||||||
Low Freq Trip
|
47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz
|
||||||||
High Freq Trip
|
55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz
|
||||||||
Overload protection (SMPS load)
|
Circuit Breaker
|
||||||||
Output Short circuit protection
|
Circuit Breaker
|
||||||||
Bypass breaker rating
|
10A | 20A | 30A | 40A | 40A | 40A | 50A | 80A | 80A |
Transfer switch rating
|
30Amp
|
40Amp
|
80Amp
|
||||||
Bypass without battery connected
|
Yes (Optional)
|
||||||||
Max bypass current
|
30Amp
|
40Amp
|
80Amp
|
||||||
Mounting
|
Wall Mount
|
||||||||
Inverter Dimensions(L* W*H)
|
340*
420*
200mm
|
425*375*200mm
|
560*420*235mm
|
655*490*240mm
|
|||||
Inverter Housing size (L*W*H)
|
415*
440*
300mm
|
500*495*300mm
|
660*470*310mm
|
720*470*290mm
|
|||||
Inverter Weight(Solar Chg)KG
|
16
|
20
|
26.5
|
31.5
|
33.5
|
37.5
|
56.5
|
58.5
|
61.5
|
Shipping Weight(Solar Chg)KG
|
19
|
22
|
29.5
|
38
|
40
|
44
|
63.5
|
66
|
68.5
|
Display
|
Status LEDs / Status LEDs+LCD
|
||||||||
Standard warranty
|
2 year(Optional)
|